- Abstract
The introduction of the AQC boiler has complex effects on the temperature of Tertiary air, traditional PID is difficult to achieve the effective control. Combined the method of the conventional PID with the fuzzy control theory, a fuzzy self-tuning PID controller is designed. Compared with traditional PID, results of simulation show that the fuzzy PID controller improves not only the adaptability and robustness of the system, but also the system's static and dynamic performance.
- Copyright
- © 2013, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Junchao Zhang AU - Shaohong Jing PY - 2013/04 DA - 2013/04 TI - Research On Fuzzy Pid Control System Of Temperatuer For Tertiary Air BT - Proceedings of the 2nd International Conference On Systems Engineering and Modeling (ICSEM 2013) PB - Atlantis Press SP - 68 EP - 71 SN - 1951-6851 UR - https://doi.org/10.2991/icsem.2013.14 DO - 10.2991/icsem.2013.14 ID - Zhang2013/04 ER -