Proceedings of the 3rd Annual International Conference on Electronics, Electrical Engineering and Information Science (EEEIS 2017)

Experimental Study on the Influence of Pulse Load on Micro - grid Operating Characteristics

Authors
Chuang LV, Pu XIE, Zhi-Yong YIN
Corresponding Author
Chuang LV
Available Online September 2017.
DOI
10.2991/eeeis-17.2017.25How to use a DOI?
Keywords
Pulse Load, Microgrid, Voltage Distortion Rate, Experimental Study
Abstract

The structure of Pulse load is complicated and the load characteristics is closely related to the work mode, in order to study the micro grid operation characteristics under pulse load and the different parameters of pulse load on the influence of the micro grid operation characteristics. This paper built a test system of diesel generator sets and pulse load and established the pulse load simulator, and defined the calculation formula of the voltage fluctuation under the premise of considering the system frequency fluctuation. Analyzed the influence law on voltage and frequency fluctuation , power transmission efficiency and the voltage distortion degree in different working mode of pulse load through changed the duty ratio, working cycle and peak power. Results show that the micro grid operation characteristics has a great relationship with the operation mode of pulse load, and different pulse load parameters on the micro grid operation characteristics of the influence law and degree is different.

Copyright
© 2017, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 3rd Annual International Conference on Electronics, Electrical Engineering and Information Science (EEEIS 2017)
Series
Advances in Engineering Research
Publication Date
September 2017
ISBN
10.2991/eeeis-17.2017.25
ISSN
2352-5401
DOI
10.2991/eeeis-17.2017.25How to use a DOI?
Copyright
© 2017, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Chuang LV
AU  - Pu XIE
AU  - Zhi-Yong YIN
PY  - 2017/09
DA  - 2017/09
TI  - Experimental Study on the Influence of Pulse Load on Micro - grid Operating Characteristics
BT  - Proceedings of the 3rd Annual International Conference on Electronics, Electrical Engineering and Information Science (EEEIS 2017)
PB  - Atlantis Press
SP  - 172
EP  - 176
SN  - 2352-5401
UR  - https://doi.org/10.2991/eeeis-17.2017.25
DO  - 10.2991/eeeis-17.2017.25
ID  - LV2017/09
ER  -