RAID Storage Systems with Early-warning and Data Migration
- DOI
- 10.2991/citcs.2012.175How to use a DOI?
- Keywords
- early-warning; data migration; reliability
- Abstract
This paper proposes a new RAID-based system, we defined as REM: RAID system with Early-warning and data Migration. REM can predict RAID potential fault according to disk health degree and array health. Once the fault has been predicted, it takes data migration to protect the data, which allocates reserved space in every disk and arranges to redirect the data in the non-repairable sectors to the reserved space; when the number of the bad sectors in the disk exceeds threshold or the disk is in poor health, the system will copy data of the unreliable disk to a new one; when an array of multiple arrays earlywarning, data can be moved into other backup array of the multiple arrays. Test results show that REM can enhance the reliability of system and reduce the entire system's performance
- Copyright
- © 2012, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Yin Yang AU - Zhihu Tan AU - Wei Liang AU - ChangSheng Xie PY - 2012/11 DA - 2012/11 TI - RAID Storage Systems with Early-warning and Data Migration BT - Proceedings of the 2012 National Conference on Information Technology and Computer Science PB - Atlantis Press SP - 684 EP - 688 SN - 1951-6851 UR - https://doi.org/10.2991/citcs.2012.175 DO - 10.2991/citcs.2012.175 ID - Yang2012/11 ER -