Research and Design of 16-bit A/D Sample Circuit Based on ADS1146
- DOI
- 10.2991/meici-16.2016.155How to use a DOI?
- Keywords
- Data sample; Programmable gain amplifier; Software filtering
- Abstract
Analog signal often sampled by A/D conversion in engineering practice,due to external interference and incorrect circuit design, will cause sample accuracy reduce. In order to rejection interference, first a differential input voltage will be magnified by instrumentation, it can rejection noise first, then input amplify signal to TEXAS INSTRUMENTS's ADS1146, it's programmable gain amplifier(PGA) can magnify signal again and internal digital filter can filtering signal again.TL431 can provide precision programmable reference voltage to ADC in order to improve converter accuracy. Finally using software algorithm to reduce interference again The test result shows that this design method can make sample data stable and improve converter accuracy, it has practical value.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Jian Huang PY - 2016/09 DA - 2016/09 TI - Research and Design of 16-bit A/D Sample Circuit Based on ADS1146 BT - Proceedings of the 2016 6th International Conference on Management, Education, Information and Control (MEICI 2016) PB - Atlantis Press SP - 744 EP - 748 SN - 1951-6851 UR - https://doi.org/10.2991/meici-16.2016.155 DO - 10.2991/meici-16.2016.155 ID - Huang2016/09 ER -