Research on Mass Ratio in Secondary Vibration Isolation
- DOI
- 10.2991/ifeesm-15.2015.21How to use a DOI?
- Keywords
- secondary vibration isolation, vibration isolation frame, mass ratio, resonance frequency, sound transmission in solid, spring
- Abstract
The secondary vibration isolation may be used to abate sound transmission in solid in the application of damping and noise reduction treatment engineering, which can have an ideal effect. The secondary vibration isolation system has a natural low frequency so it can isolate low frequency vibration. The choice of vibration isolation frame mass or ratio of vibration isolation frame mass and unit mass is key technology. Resonant mass ratio range may be abtained by way of research on the relationship between frequency ratio and mass ratio. The relationship between vibration isolation efficiency and mass ratio may be figured out through the example. The ratio of vibration isolation frame mass in secondary vibration isolation affects system’s resonance frequency. Resonance frequency can be escaped when mass ratio is above 0.3. Better efficiency can be gained through big mass ratio when necessary.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Hao Wu AU - Min Chen PY - 2015/09 DA - 2015/09 TI - Research on Mass Ratio in Secondary Vibration Isolation BT - Proceedings of the 2015 International Forum on Energy, Environment Science and Materials PB - Atlantis Press SP - 100 EP - 103 SN - 2352-5401 UR - https://doi.org/10.2991/ifeesm-15.2015.21 DO - 10.2991/ifeesm-15.2015.21 ID - Wu2015/09 ER -