The Full Process Axial Tension Test of Reactive Power Concrete
- DOI
- 10.2991/icaemt-15.2015.22How to use a DOI?
- Keywords
- Reactive powder concrete; Full process test of axis tension; Stress-strain curve;
- Abstract
The full process axial tension test is conducted for reactive powder concrete (RPC) with three kinds of steel fiber volume ratios. The dumbbell test piece with varying section of arc transition is adopted in the test with copper washer of varying thickness to address the problem that it is easy for outer clamp test piece to have stress concentration at the end. As suggested by the test results, the axial tension stress-strain curve can be measured on the normal universal tester for RPC axial tension test piece of Vf 1 and 2% without adding any rigid auxiliary facility. The damage type of RPC axial tension changes from brittle fracture to ductile damage when there is no fiber.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Hai-Yan Yuan AU - Fang-Fang Jia AU - Chun-Mei Zhu PY - 2015/08 DA - 2015/08 TI - The Full Process Axial Tension Test of Reactive Power Concrete BT - Proceedings of the 2015 International Conference on Advanced Engineering Materials and Technology PB - Atlantis Press SP - 108 EP - 111 SN - 2352-5401 UR - https://doi.org/10.2991/icaemt-15.2015.22 DO - 10.2991/icaemt-15.2015.22 ID - Yuan2015/08 ER -