Seismic Experiments on Spring Vibration Isolation Foundation of Turbine Generator under Frequent Earthquake, Fortification Earthquake and Rarely Met Earthquake
Authors
Yanzhi Liu, Tiejun Qu
Corresponding Author
Yanzhi Liu
Available Online November 2015.
- DOI
- 10.2991/icache-15.2015.72How to use a DOI?
- Keywords
- Turbine generator foundation; Spring vibration isolated; Pseudo-dynamic testing; Seismic response
- Abstract
In this paper, the model tests of 7 degree frequent earthquake, 7 degree fortification earthquake and 7 degree rarely met earthquake are carried out by using the seismic ground motion parameters of a design reference period of 60 years. Displacement of platen and columns, restoring force of foundation and reinforcement strain are obtained, as well as the position and development of cracks. The research shows that the spring vibration isolation foundation has good working performance under earthquake, and the vibration springs has certain effect of decreasing vibration.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Yanzhi Liu AU - Tiejun Qu PY - 2015/11 DA - 2015/11 TI - Seismic Experiments on Spring Vibration Isolation Foundation of Turbine Generator under Frequent Earthquake, Fortification Earthquake and Rarely Met Earthquake BT - Proceedings of the 2015 International Conference on Architectural, Civil and Hydraulics Engineering PB - Atlantis Press SP - 371 EP - 375 SN - 2352-5401 UR - https://doi.org/10.2991/icache-15.2015.72 DO - 10.2991/icache-15.2015.72 ID - Liu2015/11 ER -