Analysis of Influencing Factors of Magnetic Flux Leakage Testing Metal Tank Bottom Based on Finite Element Method
Authors
Longgang Li, Rui Duan, Wen Liu, Yaning Zhang
Corresponding Author
Longgang Li
Available Online April 2017.
- DOI
- 10.2991/amsce-17.2017.6How to use a DOI?
- Keywords
- magnetic flux leakage inspection; finite element simulation; oil storage tank bottom detection
- Abstract
In this paper, the magnetic flux leakage testing equipment of military metal oil tank is taken as the research object, and a finite element model is established by numerical simulation. The impact of the defect depth, liftoff value and plate curvature on magnetic flux leakage was calculated. The results of this study can guide the safe operation of military oil tank inspection technology, in order to ensure the quality of military oil to provide support, with greater military and economic benefits.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Longgang Li AU - Rui Duan AU - Wen Liu AU - Yaning Zhang PY - 2017/04 DA - 2017/04 TI - Analysis of Influencing Factors of Magnetic Flux Leakage Testing Metal Tank Bottom Based on Finite Element Method BT - Proceedings of the 2017 International Conference on Advanced Materials Science and Civil Engineering (AMSCE 2017) PB - Atlantis Press SP - 20 EP - 23 SN - 2352-5401 UR - https://doi.org/10.2991/amsce-17.2017.6 DO - 10.2991/amsce-17.2017.6 ID - Li2017/04 ER -