Abstract

Background: Mathematical modelling of pressure and flow waveforms in blood vessels using pulse wave propagation (PWP) models could support clinical decision-making. For a personalised model outcome, measurements of all modelled vessel radii and wall thicknesses are required. In clinical practice, however, datasets are often incomplete. To overcome this problem, we hypothesised that the adaptive capacity of blood vessels in response to mechanical load can be utilised to fill in the gaps of incomplete patient-specific datasets.

Methods: We implemented homeostatic feedback loops in a validated PWP model [1] to allow adaptation of vessel geometry to maintain wall stress and wall shear stress. To evaluate our approach, we utilised complete datasets of 10 patients scheduled for vascular access surgery. Datasets comprised of wall thicknesses and radii of 7 central and 11 arm arterial segments. We simulated reference models (RefModel, n = 10) using complete data and adapted models (AdaptModel, n = 10) using data of one brachial artery segment only. The remaining AdaptModel geometries were estimated using adaptation. In both models, mean brachial pressure, brachial artery distensibility, heart rate and aortic inflow were prescribed. We evaluated agreement between RefModel and AdaptModel geometries, as well as between pressure and flow waveforms of both models.

Results: Limits of agreement (bias±1.96SD) between AdaptModel and RefModel radii and wall thicknesses were 0.029±1.3mm and 28±230μm, respectively. AdaptModel pressure and flow waveform characteristics across the proximal-to-distal arterial domain were within the uncertainty bounds of the RefModel (Fig. 1).

Figure 1

AdaptModel and RefModel pressure and flow waveforms at three arterial locations. For adequate comparison between the AdaptModel and the RefModel a total of 100 RefModel realisations were generated within the measurement uncertainty. The median RefModel is indicated by the blue dotted curves.

Conclusions: Our adaptation-based PWP model enables personalisation even when not all required data is available.

Open Access
This is an open access article distributed under the CC BY-NC license.

Reference

[1]:W Kroon, W Huberts, M Bosboom, and F van de Vosse, A numerical method of reduced complexity for simulating vascular hemodynamics using coupled 0D lumped and 1D wave propagation models, Computational and mathematical methods in medicine, 2012, 2012.
Journal
Artery Research
Volume-Issue
20 - C
Pages
79 - 80
Publication Date
2017/12/06
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2017.10.107How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - Maarten Heusinkveld
AU  - Koen Reesink
AU  - Theo Arts
AU  - Wouter Huberts
AU  - Tammo Delhaas
PY  - 2017
DA  - 2017/12/06
TI  - P125 USE OF VASCULAR ADAPTATION IN RESPONSE TO MECHANICAL LOADING FACILITATES PERSONALISATION OF A ONE-DIMENSIONAL PULSE WAVE PROPAGATION MODEL
JO  - Artery Research
SP  - 79
EP  - 80
VL  - 20
IS  - C
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2017.10.107
DO  - 10.1016/j.artres.2017.10.107
ID  - Heusinkveld2017
ER  -