Artery Research

Volume 3, Issue 4, December 2009, Pages 192 - 192

P10.07 A PPG MEASUREMENT SETUP AND PULSE WAVE ANALYSIS FOR ARTERIAL STIFFNESS

Authors
M.J. Huotari, K. Maatta, J. Kostamovaara
University of Oulu, Oulu, Finland
Available Online 3 December 2009.
DOI
10.1016/j.artres.2009.10.138How to use a DOI?
Abstract

The light energy absorption of whole blood in the visible and infrared range is partly caused by the oxidized and reduced haemoglobin. The measurement principle can be applied for photoplethysmography (PPG). Our PPG measures the blood flux in human vessels with means of red and infrared light absorption. The absorption of light varies with the oxygen concentration and amount of blood in vessels. The PPG device has phase sensitive detection electronics which proved to be a good solution for the measurement of small absorption signals simultaneously at two different wavelengths, 660 and 940nm. In practice, the PPG waveforms, called pulse waves, can be rapidly and simply acquired by a PIN photodiode which measures the transmission of red and infra-red LED light through the forefinger and the second toe simultaneously. The waveforms are characteristics for the young person but different for the elderly person. The four template waveforms are in the consideration for waveform analysis and we get the accurate results enough.

The PPG amplitude can increase and decrease caused by the autonomic fluctuation. In the wave analysis, the first wave is called a percussion wave, the second is called tidal wave, and the third is a dicrotic. The PPG measurements may provide cheap, simple and accurate methods of diagnosing arterial and, especially vascular diseases. Moreover, further development of the theoretical model that correlates the waveform of the detected finger tip wave caused by heartbeat oscillations and the hemodynamic parameters could improve the accuracy of the method and potentially lead to a better quantification of the measured parameters used for arterial stiffness.

Open Access
This is an open access article distributed under the CC BY-NC license.

Journal
Artery Research
Volume-Issue
3 - 4
Pages
192 - 192
Publication Date
2009/12/03
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2009.10.138How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - M.J. Huotari
AU  - K. Maatta
AU  - J. Kostamovaara
PY  - 2009
DA  - 2009/12/03
TI  - P10.07 A PPG MEASUREMENT SETUP AND PULSE WAVE ANALYSIS FOR ARTERIAL STIFFNESS
JO  - Artery Research
SP  - 192
EP  - 192
VL  - 3
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2009.10.138
DO  - 10.1016/j.artres.2009.10.138
ID  - Huotari2009
ER  -