Research on AMR Sensors' Anti-interference Circuit
- DOI
- 10.2991/mecae-17.2017.20How to use a DOI?
- Keywords
- Anisotropic Magneto resistive Sensor; HMC2003; Set/Reset Circuit; Anti-interference.
- Abstract
Aiming at the problems of the decline of both accuracy and sensitivity of the anisotropic magneto resistive (AMR) sensors caused by outside interference, this paper puts forward the applied set or reset pulse to generate strong magnetic field to restore and solve the problem, and takes 3-axis AMR sensor HMC2003 as an example, introducing its basic parameters, analyzing the working principle of Set/Reset (SR) pulse and simulating the SR circuit composed of filed effect transistors. Finally, relevant experiments are done with this circuit. The experimental results show that the sensor with SR circuit has a stronger anti-interference capability and a higher detection accuracy than the one without SR circuit in the geomagnetic field.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Qi Zhang AU - Yingtang Zhang AU - Zhining Li PY - 2017/03 DA - 2017/03 TI - Research on AMR Sensors' Anti-interference Circuit BT - Proceedings of the 2017 International Conference on Mechanical, Electronic, Control and Automation Engineering (MECAE 2017) PB - Atlantis Press SP - 113 EP - 116 SN - 2352-5401 UR - https://doi.org/10.2991/mecae-17.2017.20 DO - 10.2991/mecae-17.2017.20 ID - Zhang2017/03 ER -