Abstract

Along with the development of electronics technology, electrical loads are also developing. Originally, electrical loads are linear. However, as a result of the development of electronics technology, a non-linear electrical loads appear. Non-linear loads installed in a single phase power system such as computers, air conditioners, televisions, and energy saving lamps can produce current or voltage harmonic distortion. The greater the harmonic content of a system, the worse the quality of the power it produces. The use of harmonic filters in electrical power systems has been proven to be able to reduce voltage and current harmonic distortions caused by non-linear loads. The active filters is one solution to harmonic interference problem. This research aims to study the performance of active filters to compensate harmonics currents that can improve the quality of power in residential houses. The result obtained from this research is that electrical loads in residential houses have very high harmonics components, with Total Harmonic Distortion (THDi) reaching up to 183%. By installing an active filter in parallel with the non-linear loads, THDi could be reduced up to 9.5%.

Copyright
© 2020, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the International Seminar of Science and Applied Technology (ISSAT 2020)
Series
Advances in Engineering Research
Publication Date
22 December 2020
ISBN
10.2991/aer.k.201221.027
ISSN
2352-5401
DOI
10.2991/aer.k.201221.027How to use a DOI?
Copyright
© 2020, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Hasan Surya
AU  - Sarjono Wahyujadmiko
PY  - 2020
DA  - 2020/12/22
TI  - Single Phase Active Filter Performance Study For Electrical Loads In Residential Home
BT  - Proceedings of the International Seminar of Science and Applied Technology (ISSAT 2020)
PB  - Atlantis Press
SP  - 157
EP  - 160
SN  - 2352-5401
UR  - https://doi.org/10.2991/aer.k.201221.027
DO  - 10.2991/aer.k.201221.027
ID  - Surya2020
ER  -