Research and Application of SO2 Concentration Monitoring Algorithm in Flue Gas
- DOI
- 10.2991/icsnce-18.2018.29How to use a DOI?
- Keywords
- Differential Optical Absorption Spectroscopy; SO2 Monitoring; Mixed Gas; Spectral Overlap Absorption; Cyclic Iterative Algorithm
- Abstract
This paper mainly focuses on the concentration calculation of SO2 in flue gas. There are many methods for smoke detection. First of all, this paper mainly introduces the basic Differential Optical Absorption Spectroscopy technology. Then, in order to solve the problem of overlapping absorption between different gases in the flue gas, this paper use cyclic iteration algorithm to measure the concentration of SO2. It is concluded that the basic DOAS algorithm has a large error for the concentration measurement of mixed gas with overlapping absorption, the error is above 25%. However, the cyclic iterative algorithm has a good effect on processing with it which can get a more stable result after three iterations, and the measurement error can be controlled finally within 2%.
- Copyright
- © 2018, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Wang Qinqin AU - Su Xiaohui PY - 2018/04 DA - 2018/04 TI - Research and Application of SO2 Concentration Monitoring Algorithm in Flue Gas BT - Proceedings of the 2018 Second International Conference of Sensor Network and Computer Engineering (ICSNCE 2018) PB - Atlantis Press SP - 142 EP - 147 SN - 2352-538X UR - https://doi.org/10.2991/icsnce-18.2018.29 DO - 10.2991/icsnce-18.2018.29 ID - Qinqin2018/04 ER -