Study on the gas movement in oxy-fuel combustion heating furnace
- DOI
- 10.2991/icmeit-16.2016.61How to use a DOI?
- Keywords
- oxy-fuel combustion heating furnace; FDS; gas movement; correlation analysis
- Abstract
In order to study the gas movement in oxy-fuel combustion heating furnace, the fire simulation software FDS (Fire Dynamics Simulator) is used to build the simplified model of oxy-fuel combustion heating furnace and carry on the correlation analysis of simulation parameters and mesh number which impact the calculation accuracy. Based on the above correlation analysis, the numerical calculation of the gas movement in the cold state oxy-fuel combustion heating furnace at different nozzle speeds is carried out, and the calculated results are compared with the experimental results measured by the hot wire anemometer to verify the correctness of the simulation. The results suggest that the maximum reflux region increases with the increase of the air velocity and has a certain time delay under the condition of experiment speed, which provides a reference for the ignition delay of the thermal state oxy-fuel combustion heating furnace.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Yongfu Wu AU - Guanglei Zhao AU - Liangliang Li AU - Zhongxing Liu PY - 2016/08 DA - 2016/08 TI - Study on the gas movement in oxy-fuel combustion heating furnace BT - Proceedings of the 2016 International Conference on Mechatronics Engineering and Information Technology PB - Atlantis Press SP - 322 EP - 328 SN - 2352-5401 UR - https://doi.org/10.2991/icmeit-16.2016.61 DO - 10.2991/icmeit-16.2016.61 ID - Wu2016/08 ER -