Research on Fault Location Method of VSWR for GSM-R System Leaky Cable
Authors
Jinxi Guo, Yang Liu, Duan Li, Xiucao Han
Corresponding Author
Jinxi Guo
Available Online December 2016.
- DOI
- 10.2991/icmcm-16.2016.72How to use a DOI?
- Keywords
- GSM-R; leaky coaxial cable; VSWR; fault location
- Abstract
The security and stability of GSM-R wireless communication system plays an important role in the maintenance of railway operation. According to the GSM-R system, this paper gives the system composition of GSM-R, calculates the transmission loss of leaky coaxial cable and analyzes the common faults of leaky coaxial cable. This paper analyzes the principle of the VSWR method, and the steps of the method in the testing process and the matters needing attention in the implementation.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Jinxi Guo AU - Yang Liu AU - Duan Li AU - Xiucao Han PY - 2016/12 DA - 2016/12 TI - Research on Fault Location Method of VSWR for GSM-R System Leaky Cable BT - Proceedings of the 2016 7th International Conference on Mechatronics, Control and Materials (ICMCM 2016) PB - Atlantis Press SP - 362 EP - 366 SN - 2352-5401 UR - https://doi.org/10.2991/icmcm-16.2016.72 DO - 10.2991/icmcm-16.2016.72 ID - Guo2016/12 ER -