Proceedings of the International Conference on Innovation in Science and Technology (ICIST 2020)

Prototype of Air Neutralizer Equipment Based on Temperature Sensor and Dust Particle in Reducing the Number of Bacteria in Bedrooms of Tb Patients in the Johar Baru Puskesmas Region-Central Jakarta

Authors
Syarifah M. Jannah1, 2, *
1Department of Environmental Health, Health Polytechnic Ministry of Health of Jakarta II, Jakarta, Indonesia
2Centre for Excellence - Development, Testing, and Calibration of Medical Devices, Health Polytechnic Ministry of Health of Jakarta II, Jakarta, Indonesia
Indah N. Handayani1, 2
1Centre for Excellence - Development, Testing, and Calibration of Medical Devices, Health Polytechnic Ministry of Health of Jakarta II, Jakarta, Indonesia
2Department of Environmental Health, Health Polytechnic Ministry of Health of Jakarta II, Jakarta, Indonesia
Imas Latifah
Department of Technical Laboratory Medic, MH. Thamrin University, Jakarta, Indonesia
Iis Lestariyati
Puskesmas Johar Baru, Central Jakarta, Indonesia
Corresponding Author
Syarifah M. Jannah
Available Online 30 November 2021.
DOI
10.2991/aer.k.211129.003How to use a DOI?
Keywords
prototype air neutralizer; air quality; number of air microorganisms
Abstract

Tuberculosis cases continue to increase, so in eliminating TB cases, the right way must be sought and have high leverage. Stopping airborne transmission is an action that can be done quickly. This research has developed a prototype of a “room neutralizer”, which can kill microorganisms in the air. The DS18b20 sensor is used to detect temperature and the GP2Y1010AU sensor detects PM10 dust particulates, the Arduino Uno as the Main Control Unit is displayed with an LCD. The working principle of the tool when detecting temperature and dust particles in the high air will suck in air and pass it through the HEPA filter and closed UV lamp which is then removed again. Trials were carried out in 20 bedrooms of TB patients with an air neutralizer placed for 24 hours, and the number of germs was measured before and after the device was installed. It was found that the tool was able to reduce the number of bacteria up to 76.79% and reduce the number of fungi to 96.97%, but there was no difference in the ability to reduce the number of bacteria and fungi (sig> 0.05) before and after the air neutralizer was installed.

Copyright
© 2021 The Authors. Published by Atlantis Press International B.V.
Open Access
This is an open access article under the CC BY-NC license.

Download article (PDF)

Volume Title
Proceedings of the International Conference on Innovation in Science and Technology (ICIST 2020)
Series
Advances in Engineering Research
Publication Date
30 November 2021
ISBN
978-94-6239-472-8
ISSN
2352-5401
DOI
10.2991/aer.k.211129.003How to use a DOI?
Copyright
© 2021 The Authors. Published by Atlantis Press International B.V.
Open Access
This is an open access article under the CC BY-NC license.

Cite this article

TY  - CONF
AU  - Syarifah M. Jannah
AU  - Indah N. Handayani
AU  - Imas Latifah
AU  - Iis Lestariyati
PY  - 2021
DA  - 2021/11/30
TI  - Prototype of Air Neutralizer Equipment Based on Temperature Sensor and Dust Particle in Reducing the Number of Bacteria in Bedrooms of Tb Patients in the Johar Baru Puskesmas Region-Central Jakarta
BT  - Proceedings of the International Conference on Innovation in Science and Technology (ICIST 2020)
PB  - Atlantis Press
SP  - 10
EP  - 14
SN  - 2352-5401
UR  - https://doi.org/10.2991/aer.k.211129.003
DO  - 10.2991/aer.k.211129.003
ID  - Jannah2021