Proceedings of the 2018 7th International Conference on Energy and Environmental Protection (ICEEP 2018)

Influence of coil characteristics on sensor sensitivity of permeability testing technology based on constant current source

Authors
Xianzhi Ren, Shangkun Ren
Corresponding Author
Xianzhi Ren
Available Online September 2018.
DOI
10.2991/iceep-18.2018.314How to use a DOI?
Keywords
nondestructive testing; permeability testing; excitation coil; detection coil; detection sensitivity
Abstract

The permeability testing technology is a kind of non-destructive testing method, which based on the change of permeability, can detect the stress concentration state and the degree of fatigue damage for ferromagnetic samples. The detection sensor based on the constant current source has higher detection sensitivity, which overcomes the current negative feedback effect caused by the change of the magnetic circuit impedance of the ordinary constant voltage source. According to the principle of permeability detection, the influence of the number of turns of excitation coil, the number of turns of detection coil on the detection sensitivity were studied. The study shows that the detection sensitivity increases first with the increase of the number of turns of the excitation coil and then approaches the constant. The detection sensitivity increases as the number of turns of the detection coil increase, which is approximately linear relationship. The research can provide reference for the development of high sensitivity magnetic permeability detector.

Copyright
© 2018, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2018 7th International Conference on Energy and Environmental Protection (ICEEP 2018)
Series
Advances in Engineering Research
Publication Date
September 2018
ISBN
10.2991/iceep-18.2018.314
ISSN
2352-5401
DOI
10.2991/iceep-18.2018.314How to use a DOI?
Copyright
© 2018, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Xianzhi Ren
AU  - Shangkun Ren
PY  - 2018/09
DA  - 2018/09
TI  - Influence of coil characteristics on sensor sensitivity of permeability testing technology based on constant current source
BT  - Proceedings of the 2018 7th International Conference on Energy and Environmental Protection (ICEEP 2018)
PB  - Atlantis Press
SP  - 1727
EP  - 1731
SN  - 2352-5401
UR  - https://doi.org/10.2991/iceep-18.2018.314
DO  - 10.2991/iceep-18.2018.314
ID  - Ren2018/09
ER  -