Analysis on Invulnerability and Real-Time Performance for Smart Grid Network
- DOI
- 10.2991/iccnce.2013.181How to use a DOI?
- Keywords
- smart grid, artificial spider web topology, the degree of invulnerability, MPLS
- Abstract
In the process of building strong smart grid, the communication technology becomes an important means that supports Intelligrid Architecture. Smart grid has strict requirements in the reliability and real-time performance of communication. MPLS can improve the service quality of power communication. Aiming at the MPLS area, this paper proposes a kind of artificial spider web topology and analyses the invulnerability. Based on this, the OPNET simulation is run for road-balancing and re-routing. The results show that the MPLS routing algorithm has strong ability of road-balancing and re-routing. It can be used to improve the real-time performance of communication.
- Copyright
- © 2013, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Xiaosheng Liu AU - Tianxiang Hai AU - Jian Zheng PY - 2013/07 DA - 2013/07 TI - Analysis on Invulnerability and Real-Time Performance for Smart Grid Network BT - Proceedings of the International Conference on Computer, Networks and Communication Engineering (ICCNCE 2013) PB - Atlantis Press SP - 722 EP - 725 SN - 1951-6851 UR - https://doi.org/10.2991/iccnce.2013.181 DO - 10.2991/iccnce.2013.181 ID - Liu2013/07 ER -