Analysis of the influence of gravel size on the temperature field of crushed stone subgrade
Authors
Shi-chen Zhao, Xue-song Mao, Bao-long Zhang
Corresponding Author
Shi-chen Zhao
Available Online May 2018.
- DOI
- 10.2991/icammce-18.2018.38How to use a DOI?
- Keywords
- Gravel roadbed, Particle size, Temperature field, ABAQUS
- Abstract
This document is based on the gravel test subgrade paved at the K3012 of the Qinghai-Tibet Highway near the Wudaoliang section, a large finite element software Abaqus is used to simulate the temperature field of gravel subgrade, and the influence of the particle size temperature field is obtained. The results show that both the 2-4cm and the 10-15cm gravel subgrade can protect the permafrost under the roadbed well, but the gravel subgrade with 6-8cm diameter is lower than that, which is more favorable to the stability of permafrost.
- Copyright
- © 2018, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Shi-chen Zhao AU - Xue-song Mao AU - Bao-long Zhang PY - 2018/05 DA - 2018/05 TI - Analysis of the influence of gravel size on the temperature field of crushed stone subgrade BT - Proceedings of the 2018 3rd International Conference on Advances in Materials, Mechatronics and Civil Engineering (ICAMMCE 2018) PB - Atlantis Press SP - 163 EP - 167 SN - 2352-5401 UR - https://doi.org/10.2991/icammce-18.2018.38 DO - 10.2991/icammce-18.2018.38 ID - Zhao2018/05 ER -