Research on Numerical Analysis of the Temperature Difference of Concrete Hydration of Box Girder Bridge
- DOI
- 10.2991/eame-15.2015.142How to use a DOI?
- Keywords
- box Girder Bridge; temperature difference; numerical analysis; temperature test
- Abstract
Based on the temperature data of a post-tensioned continuous concrete box-girder bridge monitoring during concrete hydration, numerical analysis of the temperature in the different positions of the concrete box girder section was systemically carried out to extract the max temperature difference. A numerical analysis method for predicting the extremism temperature of concrete box-girder was proposed. The results show that a large temperature difference between inside and outside concrete occurred in the course of hardening of concrete. When estimating the temperature difference in concrete box-girder construction, the temperature difference must be considered.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - X. Lei AU - Y. Yao AU - Z.G. Guo PY - 2015/07 DA - 2015/07 TI - Research on Numerical Analysis of the Temperature Difference of Concrete Hydration of Box Girder Bridge BT - Proceedings of the 2015 International Conference on Electrical, Automation and Mechanical Engineering PB - Atlantis Press SP - 500 EP - 502 SN - 2352-5401 UR - https://doi.org/10.2991/eame-15.2015.142 DO - 10.2991/eame-15.2015.142 ID - Lei2015/07 ER -