Proceedings of the 2018 2nd International Conference on Advances in Energy, Environment and Chemical Science (AEECS 2018)

Experimental study on the photovoltaic/thermal performance of heat pipe PV/T component with active air-cooled

Authors
Shuang Wang, Huilong Luo, Hao Wang
Corresponding Author
Shuang Wang
Available Online March 2018.
DOI
10.2991/aeecs-18.2018.11How to use a DOI?
Keywords
solar energy; heat transfer; PV/T components; electrical efficiency; thermal efficiency
Abstract

A heat pipe photovoltaic / thermal (PV/T) component on the basis of active air-cooled was designed and constructed. The heat pipe evaporation section was used for cooling the back plate of solar panel, and the condensation section was arranged in the air flow passage. A axial flow fan was arranged at the outlet of the air flow passage to strengthen heat transfer between heat pipe condensation section and air. The collected hot air can be used for building heating, strengthening ventilation as well as hot air drying. Under the climatic conditions in Kunming area, panel temperature, cold/ hot air temperature, electrical power, electrical efficiency, thermal power and thermal efficiency of solar PV/T component were tested and analyzed. Experimental results showed that, the PV/T component has excellent electrical and thermal performance. Under the condition of daily total solar radiation was 19.78~23.25 MJ/m2, the average daily electrical efficiency was between 10.84~12.21%, the average thermal efficiency was 26.15~31.68%, the highest panel temperature was 52.3~65.1, and the hot air temperature was up to 42.3.

Copyright
© 2018, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2018 2nd International Conference on Advances in Energy, Environment and Chemical Science (AEECS 2018)
Series
Advances in Engineering Research
Publication Date
March 2018
ISBN
10.2991/aeecs-18.2018.11
ISSN
2352-5401
DOI
10.2991/aeecs-18.2018.11How to use a DOI?
Copyright
© 2018, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Shuang Wang
AU  - Huilong Luo
AU  - Hao Wang
PY  - 2018/03
DA  - 2018/03
TI  - Experimental study on the photovoltaic/thermal performance of heat pipe PV/T component with active air-cooled
BT  - Proceedings of the 2018 2nd International Conference on Advances in Energy, Environment and Chemical Science (AEECS 2018)
PB  - Atlantis Press
SP  - 46
EP  - 51
SN  - 2352-5401
UR  - https://doi.org/10.2991/aeecs-18.2018.11
DO  - 10.2991/aeecs-18.2018.11
ID  - Wang2018/03
ER  -