Study on Performance Factors of Variable Frequency Heat Pump Water Heater
- DOI
- 10.2991/aeece-15.2015.108How to use a DOI?
- Keywords
- compressor frequency, heat pump water heater, performance factors, R290
- Abstract
The performance factors of a R290 variable frequency heat pump water heater are experimentally studied. The performance factors including COP, heating time, consumption power , compression ratio, degree of super heat and degree of sub cooling with the frequencies changing from 40Hz to 90Hz are discussed. The results show different compressor frequency has a greater influence on the size of the heat, and heat increases with the increasing of the frequency.When the outlet water flow is increased, the heat capacity and COP are improved corresponding. In addition, the compression ratio, degree of superheat is direct ration with frequency, but the degree of subcooling is reverse with it.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Zhijiang Wu AU - Yansheng Xu AU - Xuewei Zhang PY - 2015/09 DA - 2015/09 TI - Study on Performance Factors of Variable Frequency Heat Pump Water Heater BT - Proceedings of the International Conference on Advances in Energy, Environment and Chemical Engineering PB - Atlantis Press SP - 537 EP - 540 SN - 2352-5401 UR - https://doi.org/10.2991/aeece-15.2015.108 DO - 10.2991/aeece-15.2015.108 ID - Wu2015/09 ER -