Proceedings of the 2nd Annual Conference on blended learning, educational technology and Innovation (ACBLETI 2020)

Measurement the Hounsfield Unit of Alginate Impression Material Using CT-Scan Equipment to Find Equility with The Human Body Tissue

Authors
Taat Guswantoro, Astri Suppa Supratman, Imelda Sakti Asih
Corresponding Author
Taat Guswantoro
Available Online 17 June 2021.
DOI
10.2991/assehr.k.210615.070How to use a DOI?
Keywords
Alginate, CT scan, Hounsfield Unit, Soft Tissue
Abstract

Imaging using CT Scan utilizes the nature of the material that can absorb X-rays so the intensity of X-rays that penetrate the material will be attenuated. The attenuation coefficient of the material will provide information on the physical properties of it, in the image produced by CT Scan, the attenuation coefficients of the material is related to the number of Hounsfield Unit (HU). Alginate impression material is an irreversible hydrocolloid molding material that will form a gel when reacted with water without heating treatment process. The nature of alginate gel is elastic and has a fast setting time, often used in the manufacture of dentures. Alginate scanning using CT scan can provide information on alginate gel equivalents with human body tissue by comparing the HU values obtained. Alginate impression material that has been set up by using water is formed with a size of 11 x 11 cm with a thickness varying 5 mm, 7 mm and 9 mm and then scanned using CT Scan obtained an average HU of -51, which is equivalent to soft tissue such as lipid or breast.

Copyright
© 2021, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2nd Annual Conference on blended learning, educational technology and Innovation (ACBLETI 2020)
Series
Advances in Social Science, Education and Humanities Research
Publication Date
17 June 2021
ISBN
10.2991/assehr.k.210615.070
ISSN
2352-5398
DOI
10.2991/assehr.k.210615.070How to use a DOI?
Copyright
© 2021, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Taat Guswantoro
AU  - Astri Suppa Supratman
AU  - Imelda Sakti Asih
PY  - 2021
DA  - 2021/06/17
TI  - Measurement the Hounsfield Unit of Alginate Impression Material Using CT-Scan Equipment to Find Equility with The Human Body Tissue
BT  - Proceedings of the 2nd Annual Conference on blended learning, educational technology and Innovation (ACBLETI 2020)
PB  - Atlantis Press
SP  - 361
EP  - 364
SN  - 2352-5398
UR  - https://doi.org/10.2991/assehr.k.210615.070
DO  - 10.2991/assehr.k.210615.070
ID  - Guswantoro2021
ER  -