Artery Research

Volume 4, Issue 4, December 2010, Pages 153 - 154

P1.04 DETERMINATION OF BOTH NEAR AND FAR WALL BEHAVIOUR OF THE CAROTID ARTERY IN HYPERTENSIVE AND NORMOTENSIVE SUBJECTS

Authors
H. Beaussier1, J.P. Aben2, I. Masson4, E. Bozec1, P. Brands3, P. Boutouyrie1, S. Laurent1
1Hôpital Européen Georges Pompidou INSERM U970, Paris, France
2Pie Medical Imaging, Maastricht, Netherlands
3Esaote Europe, Maastricht, Netherlands
4Université Paris-Est CNRS EAC 4396, Créteil, France
Available Online 2 December 2010.
DOI
10.1016/j.artres.2010.10.009How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Introduction: Although the Artlab® echotracking device (Artlab, Esaote) determines common carotid artery (CCA) far wall thickness (FW-IMT) with high resolution, the near wall thickness (NW-IMT) is still challenging. New ultrasound software (CAAS-US, Pie medical Imaging) was developed for NW-FW-IMT measurement from radiofrequency signal.

Objectives: To compare CCA IMT between CAAS-US and standard Artlab, and to assess CAAS-US determination of NW-IMT and both near and far wall IMT variations during the cardiac cycle, in 38 treated hypertensive (HT) and 18 normotensive (NT) patients.

Methods: Diastolic outer diameter (Dd) and FW-IMT were determined with CAAS-US and Artlab. Bland-Altman test and Pearson’s correlation coefficient (R) were used to compare methodologies. With CAAS-US, NW-IMT and FW-IMT were compared. Systolo(s)-diastolic(d) variations of IMT and outer D were calculated: ΔIMT ((IMTs - IMTd)/IMTd) of NW and FW were compared to ΔD ((Ds - Dd)/Dd).

Results: No significant differences in CCA Dd and FW-IMTd were observed between two methods (R=0.97, RMSE=0.124 mm and R=0.91, RMSE=0.065 mm, respectively p<0.0001). IMTd between near and far wall are significantly correlated (R=0.73, RMSE=0.117 mm, p<0.0001). FW ΔIMT is significantly correlated to ΔD (R=0.57, RMSE=0.036 mm, p=0.0002) whereas NW ΔIMT is not (R=0.30, RMSE=0.073 mm, p=0.065).

Conclusion: CAAS-US allows determination of both near and far wall CCA IMT. Whereas FW-IMT variation during the cardiac cycle is measurable, NW-IMT is less precise and remains a challenging. These findings added to CAAS-US plaque contours ability may be useful to estimate more completely the real state of the carotid artery atherosclerotic process.

Journal
Artery Research
Volume-Issue
4 - 4
Pages
153 - 154
Publication Date
2010/12/02
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2010.10.009How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - H. Beaussier
AU  - J.P. Aben
AU  - I. Masson
AU  - E. Bozec
AU  - P. Brands
AU  - P. Boutouyrie
AU  - S. Laurent
PY  - 2010
DA  - 2010/12/02
TI  - P1.04 DETERMINATION OF BOTH NEAR AND FAR WALL BEHAVIOUR OF THE CAROTID ARTERY IN HYPERTENSIVE AND NORMOTENSIVE SUBJECTS
JO  - Artery Research
SP  - 153
EP  - 154
VL  - 4
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2010.10.009
DO  - 10.1016/j.artres.2010.10.009
ID  - Beaussier2010
ER  -